Engineering systems that involve both gas and liquid flows often rely on heat exchangers to transfer energy efficiently. Cooling water systems are a prime example: they frequently serve as the backbone for cooling gas piping systems through multiple heat exchangers. Until now, modeling these types of systems in Fathom and Arrow has required significant manual effort, forcing users to iterate between the two applications to achieve balance. With the introduction of the Cross-App Heat Exchanger Thermal Link, this process becomes automated, more accurate, and far less time-consuming.
Why This Feature Matters
Traditionally, engineers modeling a liquid-gas heat exchanger needed to alternate between Fathom (for liquid systems) and Arrow (for gas systems). Each run required manual adjustments of the heat exchanger junction inputs, followed by rerunning simulations until the two sides agreed. Not only was this process tedious and slow, but it also left room for human error – particularly when juggling multiple heat exchangers.
The new Thermal Link solves this problem by creating a direct connection between Fathom and Arrow. The two applications now run simultaneously, exchanging data automatically until a converged solution is reached. This streamlined workflow allows engineers to focus on system optimization instead of repetitive input tweaking.
How the Thermal Link Works
The Cross-App Thermal Link connects heat exchanger junctions in Fathom and Arrow, simulating the thermal interaction where liquid flows through one side and gas flows through the other. Once the link is enabled, the software takes care of the iteration loop:
By default, the tolerance is 0.1% with a maximum of 20 iterations, though users can adjust these settings as needed. Once convergence is achieved, both models retain the results and can be saved for further analysis.
What once took dozens of manual iterations can now be solved automatically in one integrated run.
Key Requirements and Setup
To use the Thermal Link effectively, there are a few setup requirements:
Once enabled, the familiar Run Model button is replaced with Run Thermal Links, signaling that the two applications are now connected.
Benefits for Engineers
The automation introduced by the Cross-App Thermal Link provides three major benefits:
For systems with multiple heat exchangers, these gains compound, offering dramatic time savings across an entire project.
A Smarter Way to Model Mixed Systems
This feature represents a significant step forward in integrating liquid and gas system modeling within the Datacor Pipe Flow Modeling ecosystem. By enabling seamless collaboration between Fathom and Arrow, the Cross-App Heat Exchanger Thermal Link ensures that engineers can achieve accurate thermal solutions without the hassle of manual iteration.
For organizations modeling large-scale cooling water and gas piping systems, this advancement will translate into faster project timelines, more reliable results, and ultimately better-performing systems.
The days of juggling spreadsheets and rerunning models by hand are over – Fathom and Arrow now handle the heavy lifting for you.